1Z0-066 100 Accuracy Features

Preparing for the 1Z0-066 100 Accuracy real exam is easier if you can select the right test questions and be sure of the answers. The 1Z0-066 100 Accuracy test answers are tested and approved by our certified experts and you can check the accuracy of our questions from our free demo. Expert for one-year free updating of 1Z0-066 100 Accuracy dumps pdf, we promise you full refund if you failed exam with our dumps. Also, we will offer good service to add you choose the most suitable 1Z0-066 100 Accuracy practice braindumps since we have three different versions of every exam product. And you can free download the demos of the 1Z0-066 100 Accuracy learning quiz. Our website offers you the most comprehensive 1Z0-066 100 Accuracy study guide for the actual test and the best quality service for aftersales.

Oracle Database 12c 1Z0-066 You can take advantage of the certification.

For most busy IT workers, 1Z0-066 - Oracle Database 12c: Data Guard Administrator 100 Accuracy dumps pdf is the best alternative to your time and money to secure the way of success in the IT filed. Our New 1Z0-066 Exam Pass4Sure study materials allow you to improve your competitiveness in a short period of time. With the help of our New 1Z0-066 Exam Pass4Sure guide prep, you will be the best star better than others.

Our 1Z0-066 100 Accuracy vce braindumps are the best preparation materials for the certification exam and the guarantee of clearing exam quickly with less effort. You can find latest 1Z0-066 100 Accuracy test answers and questions in our pass guide and the detailed explanations will help you understand the content easier. Our experts check the updating of 1Z0-066 100 Accuracy free demo to ensure the accuracy of our dumps and create the pass guide based on the latest information.

Oracle 1Z0-066 100 Accuracy - Also it is good for releasing pressure.

We think of providing the best services of 1Z0-066 100 Accuracy exam questions as our obligation. So we have patient after-sales staff offering help 24/7 and solve your problems all the way. Those considerate services are thoughtful for your purchase experience and as long as you need us, we will solve your problems. Our staff is suffer-able to your any questions related to our 1Z0-066 100 Accuracy test guide. If you get any suspicions, we offer help 24/7 with enthusiasm and patience. Apart from our stupendous 1Z0-066 100 Accuracy latest dumps, our after-sales services are also unquestionable. Your decision of the practice materials may affects the results you concerning most right now. Good exam results are not accidents, but the results of careful preparation and high quality and accuracy materials like our 1Z0-066 100 Accuracy practice materials.

Do not lose hope and only focus on your goal if you are using 1Z0-066 100 Accuracy dumps. It is a package of 1Z0-066 100 Accuracy braindumps that is prepared by the proficient experts.

1Z0-066 PDF DEMO:

QUESTION NO: 1
You are required to change the Data Guard Configuration protection mode from
MAXPERFORMANCE to MAXAVAJLABILITY using Enterprise Manager Cloud Control
Which two are true about this change?
A. If the primary database cannot write its redo to at least one synchronized standby database, then the protection level remains unchanged.
B. The primary database instance will remain up and running, if it cannot write redo to at least one synchronized standby database.
C. Transactions will not commit until all redo data needed to recover those transactions are written to the online redo log, and to the standby redo log on at least one synchronizes standby database.
D. Fast start failover can be enabled when making the chance.
E. Real time apply will be automatically turned on.
Answer: B,C

QUESTION NO: 2
You created a physical standby database PRODSBY1 from the primary database PROD using SQL and RMAN Which two are prerequisites for creating a Data Guard Broker configuration to manage these databases?
A. The standby database must have supplemental logging enabled.
B. The primary database must have FORCE LOGGING enabled
C. The DG_BROKER_START parameter must be set to TRUE for both database
instances.
D. The primary database must have supplemental logging enabled.
E. A local net service name to enable connectivity to the PRODSBY1 database instance must be defined on the primary database host.
Answer: B,C

QUESTION NO: 3
A customer has these requirements for their potential Data Guard implementation:
1. Zero data loss must still be guaranteed through the loss of any one configuration component.
2 The primary database must be protected against a regional disaster
3 . Performance overheads on the primary should be minimized as much as possible given these requirements.
4. Downtime on the primary database for any reason must be kept to a minimum.
Components referred to in the broker commands are:
Which Data Guard broker commands are needed to implement these requirements?
A. EDIT DATABASE prima SET PROPERY REDOROUTES=' (LOCAL: physt1,
FASTSYNC)'; EDIT DATABASE prima SET PROPERY REDOROUTES=' (LOCAL: fs1
SYNC)'; EDIT FAR_SYNC fs1 SET PROPERTY REDORUOTES=' (pnma: physt2 SYNC)';
EDIT CONFIGURATION SET PROTECTION MODE AS MAXAVAILABILITY
B. EDIT DATABASE prima SET PROPERY REDOROUTES=' (LOCAL: fs1 ASYNC)'; EDIT
FAR_SYNC fs1 SET PROPERTY REDORUOTES=' (prima physt FASTSYNC)'; EDIT
CONFIGURATION SET PROTECTION MODE AS MAXPROTECTION
C. EDIT DATABASE prima SET PROPERY REDOROUTES^' (LOCAL: fs1 SYNC)'; EDIT
FAR_SYNCfs1 SET PROPERTY REDORUOTES=' (prima physt ASYNC)'; EDIT
CONFIGURATION SET PROTECTION MODE AS MAXAVAILABILITY;
D. EDIT DATABASE prima SET PROPERY REDOROUTES=' (LOCAL: physt1,
FASTSYNC)'; EDIT DATABASE prima SET PROPERY REDOROUTES= (LOCAL: fs1.
FASTSYNC)'; EDIT FAR_SYNC fs1 SET PROPERTY REDORUOTES=' (prima: physt2
ASYNC)'; EDIT CONFIGURATION SET PROTECTION MODE AS MAXAVAILABILITY;
Answer: A

QUESTION NO: 4
Examine the Data Guard configuration:
Configuration Status: SUCCESS
Which two are true?
A. The observer must run on host ol5.example com and is currently not running.
B. The observer will reinstate Sheep automatically after a failover, if required.
C. The observer will mark another standby database as the failover target if the original failover target becomes unavailable.
D. The observer will detect if the primary database is unable to accept new connections
E. The former primary database will not be reinstated automatically alter a failover.
Answer: B,E

QUESTION NO: 5
Which two Data Guard features require the use of flashback database by the broker?
A. Read-Mostly physical standby implementations
B. Far Sync Instances
C. Fast-Start Failover
D. Real Time Query
E. Snapshot Standby databases
Answer: C,E

Appian ACD301 - It is a popular belief that only processional experts can be the leading one to do some adept job. So our Cisco 300-215 exam prep receives a tremendous ovation in market over twenty years. So do not splurge time on searching for the perfect practice materials, because our CompTIA CNX-001 guide materials are exactly what you need to have. To let you be familiar with our product, we list the features and advantages of the Amazon DVA-C02 study materials as follow. If you try to free download the demos on the website, and you will be amazed by our excellent SAP C_S4CPB_2502 preparation engine.

Updated: May 28, 2022

1Z0-066 100 Accuracy - Latest 1Z0-066 Study Guide & Oracle Database 12C: Data Guard Administrator

PDF Questions & Answers

Exam Code: 1Z0-066
Exam Name: Oracle Database 12c: Data Guard Administrator
Updated: June 10, 2025
Total Q&As:112
Oracle Exam 1Z0-066 Guide

  Free Download


 

PC Testing Engine

Exam Code: 1Z0-066
Exam Name: Oracle Database 12c: Data Guard Administrator
Updated: June 10, 2025
Total Q&As:112
Oracle Latest Test 1Z0-066 Certification Cost

  Free Download


 

Online Testing Engine

Exam Code: 1Z0-066
Exam Name: Oracle Database 12c: Data Guard Administrator
Updated: June 10, 2025
Total Q&As:112
Oracle 1Z0-066 Exam Fees

  Free Download


 

Latest 1Z0-066 Test Voucher

 | Shobhadoshi braindumps | Shobhadoshi real | Shobhadoshi topic | Shobhadoshi study | Shobhadoshi question sitemap